Kinco CPU304 PLC programmable logic controller
Technical Specification of CPU304 PLC controller | ||||
Performance Indexes | CPU304 | |||
K304-14AT | K304-14AR | K304-14AX | ||
CPU | 16-bit industrial | |||
Execution speed | Typical Bool instruction time: <1μS Word operation time: <96μS Arithmetic operation time for integers: <130μS Arithmetic operation time for floating points: <300μS | |||
DI Points | 8XDC24V | |||
DO Points | 6XDC24V | 6Xrelay | 3XDC24V+3Xrelay | |
User Program Memory | EEPROM, 8KB | |||
Program Backup | Permanent storage, without the need of battery//1000 instructions | |||
Memory Area | Variable storage area (V area): 2KB System storage area (SM area): 300 bytes Internal storage area (M area): 32 bytes | |||
Data Retention Characteristic | Configure with the programming software: V area, C (counter) area | |||
Retention Mode and Period | Adopt super capacitors and support a retention period of not less than 144 hours upon power failure under normal temperature. | |||
Data Backup Characteristic | Perform backup operations VB1648 ~ VB1775 according to user instructions, 128 bytes in total | |||
Backup Mode and Time | EEPROM (writing operation for 1 million times) permanent backup | |||
Floating Points | Supported; the whole V area can be used for floating points | |||
Programming Language Supported | Ladder Drawing (LD), Instruction List (IL) | |||
Instruction Set | Basic instructions: 55; expansion instructions: 251 | |||
Password Protection | Yes | |||
Max. I/O | Digital data: 14 in total (DI8, DO6); Analog data: None | |||
Counter | 64 | |||
Operation Mode of Counter | Addition, subtraction | |||
Counter Range | -32768~32767 | |||
Counting Value Retention Function | Yes | |||
Timer | 64 1 ms time base: 4 10 ms time base: 16 100 ms time base: 44 | |||
High-speed Counter | 2 single/dual-phase high-speed counters Where, single-phase counter with a maximum frequency of 20KHz dual-phase counter with a maximum frequency of 10KHz | |||
Pulse Output | 2, PTO (Pulse Train Output)/PWM (Pulse Width Modulation output); Maximum output frequency: 20 KHz | |||
Analog Potentiometer | - | |||
Interruption Function | Timing interruption: 2, 1ms resolution; Timer interruption: T2/T3, 1ms resolution; Edge interruption: 4, rising edge or falling edge optional; High-speed interruption, communication interruption | |||
Real-time Clock | - | |||
Number of Connectable Expansion Modules | - | |||
COM Port | 1, RS232 or RS485; Supported working modes: Programming, Modbus-RTU (slave), Free protocol | |||
Equipment Connected with COM Port | RS232/RS485: PC (for programming), third-party HMI panel, third-party serial communication equipment (for example, instruments, bar code reader, etc.) | |||
Input Power Supply | AC85~265V | |||
Sensor Load Power Supply | DC24V, max. 300 mA | |||
Dimensions (L*W*H) | 97X114X70mm |